Oxford Hills Comprehensive High School<!img src="/media/pdf3.png" align=left border=0> |
Description: 4.3 MMBTU/hr KOB Viessmann PYRTEC 950 Wood Chip Boiler
Contact Information
Address
256 Main Street, South Paris, ME 04281
1570 Main Street, Oxford, ME 04270
County
Oxford County
Primary Contact
Richard Colpitts
Superintendent
207-743-8972 |
Existing Site Information
Facility - Type |
Public School MSAD 17 |
Multi phase project (Y/N) |
N |
Additional phase costs ($) |
na |
Facility - Size (Total) Sq Ft |
263,000 |
Total number of Students |
|
Total number of Staff (in FTE's) |
|
Building One |
Oxford Hills Comprehensive High School |
Square Feet |
263.000 |
Age |
42 |
Pipe Distance (ft) |
|
Building Two |
na |
Square Feet |
na |
Age |
na |
Pipe Distance (ft) |
na |
Building Three |
na |
Square Feet |
na |
Age |
na |
Pipe Distance (ft) |
na |
Building Four
|
na |
Square Feet
|
na |
Age |
na |
Pipe Distance (ft) |
na |
Current system - Type |
#2 oil |
Steam (S) or Hot Water (HW) |
HW |
Current Boiler - Name of |
|
Current Boiler Age (In Years) |
14 |
Control System (Manufacturer) |
Seimens |
Current Type |
#2 oil |
Current Fuel Volume to be displaced (Gallons) |
88,543 |
Fuel Use Data (Years + Average) (Gallons) |
98,381 |
Project Information
New System Boiler - Name |
KOB |
New System Boiler - Model Number |
PYRTEC 950 |
New System Boiler - Rated Capacity |
4.3 MMBTU/hr |
Fuel Type (Chips Or Pellets) |
Chips |
New System Steam (s) or Hot Water (HW) |
HW |
Storage Type |
At Grade double wide bunker |
Storage Location |
Within existing structure |
Storage Capacity Tons |
60 |
Storage Description Notes |
one double wide undivided bay |
Fuel Primary Transport Type |
Hydraulic moving floor |
Fuel Secondary Transport Type |
Auger |
Boiler Location (Existing Space or New Space) |
New space |
If New Space - Building Description |
Brick addition to existing structure |
New Space - Size |
828 sq ft |
Thermal Storage (Y/N) |
Y |
Thermal Storage Capacity |
1,900 gallons |
System Connection(s) Description |
Full integration with existing systems |
Heat Exchanger (Y/N) |
N |
Grant Amount |
$ 898,341.00 |
Owner Cost Share |
$ 1,024,551.00 |
Total Cost |
$ 1,845,627.00 |
Application Date |
December 29, 2009 |
Completion Date |
January 12, 2012 |
Estimates
Historic Oil Use (Annual Average) (gallons) |
98,381 |
Historic Oil Use (Annual Average) (cost $$$) |
$ 238,082.00 |
Historic Fuel Volume to be Displaced (Gallons) |
88,543 |
Expected Cost of Displaced Fuel - Total $$$ |
$ 214.274.06 |
Base Fuel Price 1 (Used in Application) |
$ 2.42 |
Base Fuel Price 2 (Used in Application) |
$ - |
|
|
Wood Fuel Price (Used in Application) |
$ 50.00 |
Expected Wood Use - Tons |
1,096 |
Expected Wood Use - $$$ |
$ 54,800.00 |
|
|
Expected Annual Oil Use
(Gallons in Addition to Wood) |
9,838 |
Expected Annual Oil Cost
($$$ in Addition to Wood) |
$ 23,807.96 |
|
|
Total cost of Wood and Oil (Annual) - $$$ |
$ 78,607.96 |
Expected Annual Fuel Savings -$$$ |
$ 183,282.02 |
|
|
Expected Savings Shown in Application |
$ 153,004.00 |
Historical Data
Base Fuel Price 1 (Used in Application) |
$ 2.42 |
Base Fuel Price 2 (Used in Application) |
$ - |
Wood Fuel Price (Used in Application) |
$ 50.00 |
Five Year Fuel Use History Year 1 |
|
Calendar Year |
|
Fuel Use in Gallons |
|
Fuel Use Cost ($) |
$ |
|
Five Year Fuel Use History Year 2 |
|
Calendar Year |
|
Fuel Use in Gallons |
|
Fuel Use Cost ($) |
$ |
|
|
|
Five Year Fuel Use History Year 3 |
|
Calendar Year |
|
Fuel Use in Gallons |
|
Fuel Use Cost ($) |
$ |
|
Five Year Fuel Use History Year 4 |
|
Calendar Year |
|
Fuel Use in Gallons |
|
Fuel Use Cost ($) |
$ |
|
|
|
Five Year Fuel Use History Year 5 |
|
Calendar Year |
|
Fuel Use in Gallons |
|
Fuel Use Cost ($) |
$ |
|
|
Five Year Total Fuel Use (Gallons) |
|
Five Year Yearly Average Fuel Use (Gallons) |
|
Five Year Total Fuel Cost ($) |
$ |
Five Year Average Fuel Cost ($) |
$ |
Fuel Use
|
Year Ending |
4/30/2013 |
4/30/2014 |
4/30/2015 |
4/30/2016 |
4/30/2017 |
Cumulative
Totals |
|
PELLETS used |
919.53 |
|
|
|
|
919.53 |
(in tons) |
ACTUAL COST |
$50,114.46 |
|
|
|
|
$50,114.46 |
(cost + shipping costs) |
OIL used |
11,785 |
|
|
|
|
11,785 |
(in gallons) |
ACTUAL COST |
$56,010.14 |
|
|
|
|
$56,010.14 |
(delivered cost) |
TOTAL COST |
$106,124.60 |
|
|
|
|
$106,124.60 |
(cost of both fuels) |
|
Additional Notes
Electrostatic precipitator particulate matter capture system
Categories
Hot Water, Oxford County, Wood Chips,
Extra Files & Images:
|
|